PubMed-ID: 22146250Seiten: 520-522, Sprache: EnglischHawkinson, Roy T.The fixed implant-supported restoration of this mandibular surgical defect deliberately violated the principles of mandibular flexure, crown-to-implant ratio, and off-axis loading. A custom-made implant-mounted jig revealed no mandibular flexure in this patient, but crown-to-root ratios of up to 39:12 were unavoidable. The restoration has needed no maintenance for 14 years. This apparent success calls into question the blind application of prevailing clinical principles.