The International Journal of Prosthodontics, 2/2022
DOI: 10.11607/ijp.7115Pages 219-224, Language: EnglishKlinke, Thomas / Bratner, Siegfried / Hannak, Wolfgang / Boening, Klaus / Jakstat, Holger
Purpose: To investigate whether viewing distance influences the results of visual tooth color differentiation.
Materials and methods: A total of 65 students underwent both theoretical and practical training by a standardized lecture on the use of an internet learning module (Toothguide Trainer, VITA Zahnfabrik) and a standardized training program (Toothguide Training Box) for visual shade-taking. Each student matched 10 randomly selected shade tabs presented at different viewing distances (arm's length distance [AL, 70 cm] and AL/2 [35cm]) under lateral, non-glare lighting at a 45-degree angle with a color differentiation lamp. The results were recorded as to what extent the presented and selected tabs of the color determination matched.
Results: The overall median values of perceived color difference (ΔE) were 1.6 for AL/2 and 3.2 for AL, and these values were significantly different (P < .001).
Conclusion: Within the limitations of this study, it was shown that the viewing distance had a significant influence on the color deviation in tooth color assessment. Therefore, a smaller viewing distance of 35 cm for shade determination is recommended.
QZ - Quintessenz Zahntechnik, 3/2021
ExpertenfokusPages 238-245, Language: GermanKlinke, ThomasMetallkeramik ist eine langlebige und über viele Jahrzehnte erprobte Materialgruppe für die prothetische Versorgung. Der Beitrag beschreibt anhand zahlreicher Studien die Gründe für die Dauerhaftigkeit und für ein mögliches Versagen von Restaurationen und dokumentiert Misserfolgsraten verschiedener Versorgungen.
Keywords: Metallkeramik, festsitzende Versorgung, Langlebigkeit, Versagen, Prothetik
QZ - Quintessenz Zahntechnik, 11/2021
ErfahrungsberichtPages 1270-1275, Language: GermanKlinke, ThomasIn dem Beitrag werden die Ebenen in der Totalprothetik, die die Grundlagen der Zahnaufstellung darstellen, besprochen und die physikalischen Grundlagen einer jeden totalprothetischen Versorgung – unabhängig vom Aufstellkonzept – beschrieben. Werden die Ebenen und die physikalischen Effekte bei der Aufstellung nicht berücksichtigt bzw. nicht umgesetzt, ist die physiologische Belastung des knöchernen Teguments bzw. die Lagestabilität (insbesondere der Unterkieferprothese) nicht gewährt und die Funktionalität der totalen Prothese infrage gestellt.
Keywords: Totalprothese, Anatomie, Zahnaufstellung, Aufstellkonzept
Quintessence International, 1/2020
DOI: 10.3290/j.qi.a43755, PubMed ID (PMID): 31813942Pages 86-e11, Language: EnglishFotiadou, Christina / Frasheri, Iris / Reymus, Marcel / Diegritz, Christian / Kessler, Andreas / Manhart, Jürgen / Hickel, Reinhard / Klinke, Thomas / Heck, KatrinObjective: To compare the clinical performance of two glass-ionomer cements in combination with two light-cured coatings in Class II cavities.
Method and materials: In total, 43 Equia Fil/Equia Coat and 42 Fuji IX GP Fast/Fuji Coat LC restorations were placed, in 34 patients. Only Class II cavities with two- or three-surface restorations were included. The clinical performance was evaluated at baseline, after 1, 2, and 3 years using the FDI criteria. For the statistical analysis, Fisher exact test, Wilcoxon signed-rank test and Mann-Whitney U test were applied. The success and survival of the restorations were calculated with the Kaplan-Meier method and a log-rank test was used to detect significant differences between the tested materials.
Results: At the 3-year recall, no significant differences could be detected between the two glass-ionomer cements for any of the evaluated criteria (Mann-Whitney U test, P > .05). When comparing the baseline with the recall data at 3 years for each material separately, significant changes could be observed in both materials for the criteria "surface luster," "fracture of material and retention," and "approximal anatomical form" (Wilcoxon signed-rank test, P .05). Additionally, the Equia Fil restorations showed a notable change for the criteria "marginal adaptation" (Wilcoxon signed-rank test, P = .039). At the 3-year follow up, the Equia Fil and the Fuji IX GP Fast restorations exhibited an overall survival rate of 89.3% and 88.0%, respectively. Three fillings in each group failed.
Conclusion: The two glass-ionomer cements tested performed similarly in Class II cavities in adult patients, with a moderate failure rate after 3 years.
(Quintessence Int 2020;1:e1-e11; doi: 10.3290/j.qi.a43755. Original article published in Quintessence Int 2019;50:592-602; doi: 10.3290/j.qi.a42692)
Keywords: amalgam alternatives, Class II restorations, clinical study, Equia, FDI criteria, glass-ionomer cement, permanent teeth
Quintessence International, 8/2019
DOI: 10.3290/j.qi.a42692, PubMed ID (PMID): 31286115Pages 592-602, Language: EnglishFotiadou, Christina / Frasheri, Iris / Reymus, Marcel / Diegritz, Christian / Kessler, Andreas / Manhart, Jürgen / Hickel, Reinhard / Klinke, Thomas / Heck, KatrinObjective: To compare the clinical performance of two glass-ionomer cements in combination with two light-cured coatings in Class II cavities.
Method and materials: In total, 43 Equia Fil/Equia Coat and 42 Fuji IX GP Fast/Fuji Coat LC restorations were placed, in 34 patients. Only Class II cavities with two- or three-surface restorations were included. The clinical performance was evaluated at baseline, after 1, 2, and 3 years using the FDI criteria. For the statistical analysis, Fisher exact test, Wilcoxon signed-rank test and Mann-Whitney U test were applied. The success and survival of the restorations were calculated with the Kaplan-Meier method and a log-rank test was used to detect significant differences between the tested materials.
Results: At the 3-year recall, no significant differences could be detected between the two glass-ionomer cements for any of the evaluated criteria (Mann-Whitney U test, P > .05). When comparing the baseline with the recall data at 3 years for each material separately, significant changes could be observed in both materials for the criteria "surface luster," "fracture of material and retention," and "approximal anatomical form" (Wilcoxon signed-rank test, P .05). Additionally, the Equia Fil restorations showed a notable change for the criteria "marginal adaptation" (Wilcoxon signed-rank test, P = .039). At the 3-year follow up, the Equia Fil and the Fuji IX GP Fast restorations exhibited an overall survival rate of 86.21% and 84.0%, respectively.
Conclusion: The two glass-ionomer cements tested performed similarly in Class II cavities in adult patients, with a moderate to high failure rate after 3 years.
(Corrected article published in Quintessence Int 2020;1:e1-e11; doi: 10.3290/j.qi.a43755)
Keywords: amalgam alternatives, Class II restorations, clinical study, Equia, FDI criteria, glass-ionomer cement, permanent teeth
QZ - Quintessenz Zahntechnik, 2/2019
WissenschaftPages 168-174, Language: GermanKlinke, Thomas / Lucas, Christian / Lehmann, Falk / Biffar, ReinerIm Beitrag wird der Einfluss verschiedener Brenngutträger auf die Sinterschrumpfung bei hoch-, mittel- und niedrigbrennenden Keramiken dargestellt. Keramische Proben nach DIN EN ISO 13297/2 wurden aus sechs laborüblichen, niedrig-, mittel- und hochbrennenden Verblendkeramiken hergestellt und entsprechend der Herstellerempfehlung gesintert. Die Sinterschrumpfungen wurden als linear metrische Schrumpfung in Prozent ausgewiesen. Durch seine physikalischen Eigenschaften (Masse, Wärmeleitung und anderes) beeinflusst der eingebrachte Sinterträger die Sinterendtemperatur innerhalb der Brennkammer. In Abhängigkeit des verwendeten Verblendsystems sowie des Sinterträgers konnten unterschiedliche Einflüsse auf die Sinterschrumpfungen dargestellt werden.
Keywords: Keramik, Sintern, Schrumpfung, Verblendkeramik, Sinterträger
QZ - Quintessenz Zahntechnik, 8/2018
SciencePages 1018-1027, Language: GermanKlinke, Thomas / Delimata, Larissa / Quooß, Alexandra / Biffar, ReinerUnverzichtbare Notwendigkeit beim Umgang mit keramischen MassenKeramischen Massen wird Modellationsliquid zugesetzt, das unter anderem die Aufgabe eines Binders hat. Diesem werden vom Hersteller wiederum Additiva zugesetzt, deren ungenügende Entbinderung häufig die Ursache für Abplatzungen sind. Eine vollständige Entbinderung des Grünlings in der Vortrocknung ist daher unabdingbar. In der beschriebenen Untersuchung konnten keine Unterschiede zwischen der Modellierflüssigkeit und Wasser in der entkoppelten Vortrocknung festgestellt werden. Signifikante Unterschiede in der Entbinderungsphase gab es allerdings teilweise zwischen den metallischen Brennträgern und den keramischen Sinterträgern.
Keywords: Entbinderung, entkoppelte Vortrocknung, Modellationsliquid, Abplatzung, Frakturen, Sintern
QZ - Quintessenz Zahntechnik, 6/2018
SciencePages 808-818, Language: GermanKlinke, Thomas / Bölter, Heide / Biffar, ReinerDargestellt wird der Einfluss der Sinterparameter (Aufheizrate und Haltezeit) auf die Sintergüte unterschiedlicher keramischer Systeme. Es zeigte sich, dass die Qualität der keramischen Sinterung maßgeblich durch die Umsetzung und Anwendung suffizienter Sinterparameter bestimmt wird. Dies beinhaltet auch eine ausreichende Zeitspanne, die der Sinterzyklus erfordert. Eine Kürzung der notwendigen Sinterzeit führt zu einer Zunahme der Oberflächenrauheit, die durch zusätzliche Sinterbrände oder händisches Nacharbeiten verbessert werden muss.
Keywords: Sintern, Oberflächenrauheit, Aufheizquotient, Haltezeit, Oberflächenprofil
QZ - Quintessenz Zahntechnik, 3/2018
BlickpunktPages 401-405, Language: GermanKlinke, Thomas / Quooß, Alexandra / Biffar, ReinerQZ - Quintessenz Zahntechnik, 9/2017
BlickpunktPages 1225-1232, Language: GermanKlinke, Thomas / Lucas, Christian / Quooß, Alexandra / Biffar, ReinerZur Temperaturverteilung im Keramikofen