Purpose: The aim of the present animal study was to examine the impact of two implant designs
that promote different insertion torque values on implant stability and evaluate, histomorphometrically,
the bone healing for immediate implant placement in fresh sockets.
Materials and Methods: Twelve female sheep (35.0±5.0kg) and 48 conical Morse-taper dental
implants divided into two groups (n = 24 per group): G1 group, where the implants present
a design that can provide high insertion torque values; and G2 group, where the implants
present a design that can provide low insertion torque values. Both had the same surface
treatment, and dimensions (4.0 mm in diameter and 10 mm in length). The first two posterior
teeth (both sides) were extracted carefully. Sequentially, there were osteotomies in the mesial
socket of each molar tooth. The final implant position was 2 mm below the buccal bone crest
level. On the right side, implants of the G1 were placed anteriorly, followed by implants of
the G2; and, on the left side, it was the reverse. A digital torquemeter was used to measure the
maximum final insertion torque value (f-IT). The initial implant stability quotient (ISQ) was
measured immediately after the implant insertion (T0) and immediately after the euthanasia
and removing the mandibles with the implants. The animals were euthanized (n=6 animals/
time) at 21 days (T1) and 35 days (T2). The t-test was used to compare statistical differences
for each intragroup parameter analyzed. Pearson's correlation was used to analyze possible
correlations: f-IT and BIC%, f-IT and ISQ, and ISQ and %BIC.
Results: Regarding the insertion torque, the G1 presented higher values than the G2, with a
statistically significant difference (p<0.0001). The ISQ mean values were higher in the B-L
direction than those obtained for M-D for both groups. %BIC measurements showed higher
values in samples from G2 than G1 at both times and in both directions. New bone, medullary
spaces, and collagen matrix had statistical differences between the groups at each evaluation
time.
Conclusion: Using implants with a modified macrogeometry plays a significant role in implant
stability and the healing process of bone tissue around the implant. It is important for
clinicians to carefully consider implant macrogeometry when planning dental implant surgery
to achieve optimal implant stability and successful osseointegration, mainly in cases of immediate
implant placement.
Keywords: dental implants, macrogeometry, pre-clinical study, histomorphometry.