PubMed ID (PMID): 21841978Pages 707-717, Language: EnglishTahmaseb, Ali / De Clerck, Renaat / Eckert, Steven / Wismeijer, DanielPurpose: To describe the use of a computer-aided three-dimensional planning protocol in combination with previously placed reference elements and computer-aided design/computer-assisted manufacture (CAD/CAM) technology to restore the partially edentulous patient.
Materials and Methods: Mini-implants and/or reference brackets were inserted or positioned in specified locations in a test cast and in two patients prior to imaging to act as definitive fiducial markers. This served as a fixed base to better define a setup for the fabrication of a surgical template used during computed tomographic imaging. A simulated partially edentulous maxilla was used for the study, and two partially edentulous patients participated. With the CT images, a CAD/CAM superstructure was created prior to surgery and inserted immediately after surgery. Fit of the prosthesis was assessed using three-dimensional tension measurements with strain gauges.
Results: Mean misfit for all implants in the x-, y-, and z-axes was 26.6, 24.8, and 10.4 µm, respectively. The total misfit calculated according to the Pythagorean theorem was 42.6 µm.
Conclusions: Based upon this pilot study in two patients and an in vitro analysis, it appears that the use of reproducible fiducial markers consisting of mini-implants and reference brackets results in the fabrication of an acceptably accurately fitting definitive prosthesis prior to implant placement.
Keywords: dental implants, guided surgery, immediate loading