DOI: 10.3290/j.jad.a39619, PubMed ID (PMID): 29292408Pages 517-523, Language: EnglishNeri, Jiovanne Rabelo / Nojosa, Jacqueline de Santiago / Yamauti, Monica / Mendonça, Juliano Sartori / Santiago, Sérgio LimaPurpose: To evaluate the effect of sodium fluoride and chlorhexidine digluconate on the composite-dentin bond strength of a self-etch adhesive after thermocycling.
Materials and Methods: Eighteen human third molars were prepared to expose a flat dentin surface and were divided into 3 groups (n = 6) according to the 3 cavity cleaning solutions: distilled water, 2% chlorhexidine digluconate (CHX), or 1.23% sodium fluoride (NaF). Solutions were rubbed onto dentin surfaces for 60 s, followed by bonding with Clearfil SE Bond, and a 5-mm-thick composite crown buildup. Bonded teeth were stored in distilled water for 24 h and then longitudinally sectioned to obtain bonded sticks. Half of the specimens were immediately tested in tension at 0.5 mm/min, while the remaining specimens were tested after 60,000 thermal cycles. Data were analyzed using two-way ANOVA and the Holm-Sidak method.
Results: There was no significant difference between the groups after 24 h (p > 0.05). Thermocycling resulted in significant bond strength reduction for distilled water and CHX (p 0.05). When 24 h bond strengths were compared to the thermocycling group, NaF maintained its bond strength (p > 0.05), while significant reductions were observed for distilled water and CHX (p 0.05).
Conclusions: Pretreatment with NaF maintained the bond strength of Clearfil SE Bond to dentin after 60,000 thermal cycles, but pretreatment with CHX did not.
Keywords: dentin-bonding agents, sodium fluoride, self-etch adhesive, dentin bond strength