International Poster Journal of Dentistry and Oral Medicine, 2/2023
Poster 2532, Sprache: EnglischKahlich, Niklas / Kühnöl, Conrad / Gedrange, Tomasz / Botzenhart, Ute UlrikeQuestions: Craniomandibular dysfunctions (CMD) are dysregulations of the chewing organ and adjoining structures, which can lead to destruction of hard and soft dental tissues, joint cartilage, decreased chewing function, and pain, thereby massively reducing wellbeing and quality of life. The treatment of CMD requires accurate and objective diagnostics to enable a successful interdisciplinary treatment. Conventional diagnostics cannot completely detect the temporomandibular joint in its own complexity by technical restriction. In addition, due to a high proportion of "manual labour", human errors and diagnostic variances cannot be excluded (1).
The aim of the present study was to evaluate a full digital workflow for craniomandibular dysfunction (CMD) diagnostics, including intraoral scans, digital volume tomography, digital motion tracking, and treatment with a 3D-shaped bite splint.
Methods: This prospective study included n=19 adult patients (8 men, 11 women) suffering from CMD, who met the inclusion criteria and consented to the therapy and the use of their data. Inclusion criteria were as follows:
- presence of a craniomandibular dysfunction requiring treatment
- no previous splint therapy
- no primary temporomandibular joint disease or general underlying disease that could be the cause of the pain or could influence the therapy outcome (e.g. rickets, Parkinson's disease, osteoporosis, psychosomatic diseases, neuralgias, and neuropathies).
Prior to treatment, ethical approval was obtained by legal agency (EK 213062018). 3D diagnostics and data matching were performed, on the basis of which a 3D bite splint was designed and produced (SICAT, Bonn, Germany; Polymethylmethacrylat astron® Clearsplint® CAD/CAM, Schütz Dental GmbH, Rosbach, Germany). Patients were evaluated pre- and post-treatment and every 6 weeks up to 6 months by clinical analysis, splint adjustment, and questionnaire. Descriptive analysis and statistics were performed using MS Excel (Version 16.0, Microsoft Corporation, Redmond, USA).
Results: Splint therapy led to a significant reduction in subjective complaints in 89% (n=17) of patients, whereas only 11% (n=2) reported unchanged complaints. 74% (n=14) of patients preferred digital impressions and milled bite splints; the other 26% (n=5) did not indicate a special preference. The majority of digital designed bite splints showed a satisfactory initial fit (58%//n=11) and 32% (n=6) could be fitted after minor adjustments.
Conclusions: The digital workflow for CMD treatment, analysed in this study, showed a significant reduction in working time by a high proportion of digitization and automation combined with a high level of patient satisfaction and accuracy of splint fit. Nevertheless, the use of digital volume tomography did not improve diagnostics (2) and should be viewed critically in this context.
Schlagwörter: CMD treatment, 3D-shaped bite splints, digital workflow, economic efficiency
International Journal of Computerized Dentistry, 3/2019
Digitaler SonderdruckPubMed-ID: 31463492Seiten: 283-292, Sprache: Deutsch, EnglischKühnöl, Conrad / Kordaß, BerndEs wird ein Patientenfall mit arthrogenen CMD-Beschwerden vorgestellt, bei dem neben der klinischen eine Instrumentelle Diagnostik mit Sicat Function (Fa. Sicat, Bonn, Deutschland) durchgeführt wurde. Dazu wurden Bewegungen der Unterkieferfunktion mit einem ultraschallbasierten Messsystem (JMT+) aufgezeichnet und mit DVT-Bilddaten in Beziehung gesetzt. Ein Kopplungslöffel (Fusionbite) sicherte die räumliche Übereinstimmung. Zusätzlich wurden Ganzkieferscans (IO-Scanner Omnicam, Fa. Dentsply Sirona, Bensheim, Deutschland) mit den DVT-Daten "gematched". Aus den Bewegungsdaten wurde eine biomechanisch optimale Gelenkposition ermittelt, in der eine gefräste Aufbissschiene angefertigt wurde. In der Folge wurde das erzielte funktionelle Ergebnis mit CAD/CAM-gefertigten Provisorien und Tabletopps gesichert und bis zur definitiven Rekonstruktion mit Sicat Function kontrolliert. Dafür wurde die Bewegungsfunktion mit dem JMT+ nach jedem Behandlungsschritt erneut aufgezeichnet. Der Kopplungslöffel wurde sukzessive angepasst und ergänzt, wodurch die ursprüngliche Kieferrelation im Fusionbite beibehalten werden konnte, was die Vergleichbarkeit mit der Ausgangssituation garantierte, ohne dass ein weiteres DVT angefertigt werden musste. Sicat Function erweist sich als ein exzellentes System für den digitalen Workflow, wenn eine kontrollierte Bisslageänderung bei Patienten mit arthrogenen CMD-Beschwerden angestrebt wird.
Schlagwörter: Instrumentelle digitale Funktionsdiagnostik, Sicat Function, CAD/CAM, Cerec, Digitaler Workflow, CMD-Diagnostik, digitale Bisslageänderung