Aim: The present prospective clinical study aimed to validate the Greifswald Digital Analyzing System (GEDAS) as a method for digital assessment of the occlusion in primary and mixed dentition.
Materials and methods: The reproducibility of GEDAS in primary and mixed dentition was assessed using the intraclass correlation coefficient (ICC). In addition, the acceptability of the method to the dentist, the child, and the parent/caregiver was assessed using a modified visual analog scale of faces, the Frankl behavior scale, and the 10-point Likert scale. In total, 20 participants aged between 3 and 9 years (mean age: 6; standard deviation: ± 1.74) with primary (n = 10) and mixed (n = 10) dentition were recruited.
Results: The ICC for the number of contact points in all teeth was 0.94 and for the area of contact points was 0.97, indicating good to excellent reproducibility. The average total number of contacts per bite registration per arch in the primary and mixed dentition was 36.5 (17 to 66) and 37.9 (9 to 74), respectively. The average of the total area of interocclusal contact area in the primary and mixed dentition was 25.55 mm2 (5.39 to 70.20) and 29.59 mm2 (2.80 to 78.53), respectively. During the procedure, the majority of dentists reported the child’s behavior to be positive (85%) and found the procedure easy to perform (80%), short (6.0 min), and tolerable (80%).
Conclusion: GEDAS is an occlusal analysis tool with good acceptability and reproducibility in children and could be considered for the planning and assessment of restorative and orthodontic treatment in the intermediate stages.
Keywords: GEDAS, occlusion, digital, primary dentition, mixed dentition, bite registration