DOI: 10.11607/ijp.4089, PubMed ID (PMID): 26340013Pages 519-521, Language: EnglishNam, Se-Jin / Yoon, Mi-Jung / Kim, Won-Hee / Ryu, Gil-Ju / Bang, Min-Ki / Huh, Jung-BoThis study aimed to evaluate and compare the marginal and internal gap widths of lithium disilicate computer-aided design / computer-assisted manufacture (LDC) crowns and conventionally produced porcelain-fused-to-metal (PFM) crowns. A convenience sample of 21 patients treated with a single restoration was selected. PFM and LDC crowns were fabricated for each selected abutment tooth, following traditional crown preparation. Silicone replicas were produced, and internal gaps and marginal gaps were measured. Internal gaps were significantly larger for the axial and occlusal surfaces of LDC crowns than for those of PFM crowns (P .001). Marginal gaps were not significantly different (P > .05). Both LDC crowns and PFM crowns showed clinically acceptable marginal fit.